Transfusion · 2009 · 40 citations · 18 references
MedicineHealth InformaticsHematologyElectronic Health RecordsPatient SafetyTransfusion MedicineBlood Transfusion ManagementBlood Transfusion NursingBlood Transfusion SafetyPatient Identification VerificationPatient VerificationTransfusion SupportBarriersBenchmark IndicatorsBlood Transfusion IdentificationBlood Type MatchingMethodological Error RatesPhlebotomy SafetyTransfusion Error PreventionTransfusion Quality Assurance
BACKGROUND: This study presents our implementation of a two-specimen requirement with no prior record of ABO/Rh to verify patients' blood type before transfusion. MATERIALS AND METHODS: Blood type verification was introduced, discussed, approved, and implemented over a 12-month period (May 2007 to May 2008). Potential barriers and impact on benchmark indicators were identified and tracked. RESULTS: Inpatient identification and/or specimen labeling for nursing and laboratory phlebotomists baseline corrected error rates were 1:467 and 1:5555, respectively. This study therefore sought and obtained approval to initiate a new policy of blood type verification before blood transfusion. Compliance in turnaround time (TAT) before and after implementation for completion of STAT type and screen/crossmatch within 60 minutes worsened marginally, from 90% to 80%. The impact on use of O-, uncrossmatched blood was found to be manageable. Seven (of 25 total) recorded electronic complaints were received after implementation. The corrected error rate for nurse phlebotomy draws after implementation was 1:630. CONCLUSION: Despite the lack of an instigating event, verification of blood type before blood transfusion was successfully implemented. An impact on resources and benchmark indicators such as TAT can be anticipated and managed. Further process improvement efforts will be needed to ensure safety (e.g., at time of blood transfusion) for patients receiving blood transfusions. ABO/Rh verification may be necessary even after future implementation of bar coding and/or RFID chips, because human errors continue to occur even with systems improvements.
18
Reports of 355 transfusion‐associated deaths: 1976 through 1985
Kathleen Sazama · Transfusion · 1990 · 736 citations
Serious hazards of transfusion (SHOT) initiative: analysis of the first two annual reports
L. M. Williamson, Sarina C. Lowe, Elizabeth M. Love et al. · BMJ · 1999 · 339 citations · Full text
A report of 104 transfusion errors in New York State
Jeanne V. Linden, B Paul, K.P. Dressler · Transfusion · 1992 · 329 citations
An international study of the performance of sample collection from patients
Michael Murphy, G. Andreu, Nancy M. Heddle et al. · Vox Sanguinis · 2003 · 151 citations