Magnetic Priming at the Cathode of a Relativistic Magnetron

Brad W. Hoff, R. M. Gilgenbach, Nicholas Jordan, Y. Y. Lau, Edward J. Cruz, David M. French, M. R. Gómez, J. C. Zier, Thomas A. Spencer, David L. Price

IEEE Transactions on Plasma Science · 2008 · 32 citations · 11 references

Concepts

Abstract

Experiments have been performed in testing magnetic priming at the cathode of a relativistic magnetron to study the effects on high-power microwave performance. Magnetic priming consists of N/2 azimuthal magnetic perturbations applied to an N-cavity magnetron for rapid generation of the desired number of electron spokes for the pi-mode. Magnetic perturbations were imposed by utilizing three high-permeability nickel-iron wires embedded beneath the emission region of the cathode, spaced 120 apart. Magnetic priming was demonstrated to increase the percentage of pi-mode shots by 15% over the baseline case. Mean peak power for -mode shots was found to be higher in the magnetically primed case by almost a factor of two. Increases in mean microwave pulsewidth were also observed in the magnetically primed case when compared to the unprimed case (66-ns primed versus 50-ns unprimed). Magnetron starting current for the magnetically primed pi-mode exhibited a reduction to 69% of the unprimed baseline starting current.

References

11