Concepedia

Publication | Closed Access

Direct comparison between a programmable and a conventional Josephson voltage standard at the level of 10 V

26

Citations

13

References

2008

Year

Abstract

A Josephson voltage standard (JVS) from the BIPM, incorporating a PTB 10 V programmable array, has been compared with a JVS from the LNE, operating with a conventional hysteretic array. The metrological characteristics of both JVSs were carefully studied. We report on the experiments performed for this comparison and on the uncertainty components. The final comparison result is (UPJVS − UJVS)/UJVS = −3.2 × 10−11 with a relative total combined standard uncertainty of 6.1 × 10−11 (k = 1).

References

YearCitations