Atrial Pressures in the Seated Position

Nancy A. K. Perkins-Pearson, W. Marshall, Robert F. Bedford

Anesthesiology · 1982 · 72 citations · 0 references

DOIFull text

Open access

Concepts

Abstract

In order to investigate the circumstances in which air bubbles in the venous circulation could pass to the arterial circulation via a patent foramen ovale, simultaneous right atrial (RAP) and pulmonary capillary wedge pressures (PCWP) were determined in two patient populations undergoing elective neurosurgical procedures in the seated position. In Group 1 (n = 24), quadruple-lumen pulmonary arterial catheters were inserted prior to the induction of anesthesia, and RAP and PCWP were determined while the patients were: 1) awake and supine, 2) awake and seated, 3) anesthetized and supine, 4) anesthetized and seated, and 5) 60 minutes after skin incision. In Group 2 (n = 31), RAP and PCWP were measured prior to, and then during intraoperative episodes of clinical air embolism. In Group 1, placement in the seated position while awake resulted in a significant decrease in PCWP (8.5 mmHg ± 0.9 SE supine vs. 6.6 mmHg ± 0.9 SE seated, P