Status of the development of insertion devices for ELETTRA

B. Diviacco, R. Bracco, Carlo Poloni, R.P. Walker, D. Zangrando

Review of Scientific Instruments · 1992 · 27 citations · 1 references

Concepts

Abstract

The status of the development of insertion devices for the 1.5–2-GeV synchrotron radiation source ELETTRA is described. Recent results achieved with a prototype pure permanent magnet undulator and the construction and performance of a prototype hybrid multipole wiggler are presented. The parameters and design of the first undulator that will be constructed for ELETTRA, U12.5, are also presented, and some details are given about the magnetic measurement system.