Neurosurgery · 1996 · 172 citations · 17 references
MedicineNeurosurgerySurgeryCerebrovascular NeurosurgeryCerebrovascular SurgeryDiagnostic ImagingBrain ImagingIntraoperative NavigationNeurosurgical InstrumentsStereotactic NeurosurgeryStereotactic SurgeryClinical Test AccuracyIntraoperative GuidanceMedical Image RegistrationNavigation-assisted SurgeryOperative NavigationPatient-to-image RegistrationRegistrationSurgical Planning
OBJECTIVE: A frameless stereotactic system (the Viewing Wand; Elekta Instruments, Atlanta, GA) has been developed for use with preoperative computed tomography, magnetic resonance imaging, and positron emission tomography as an adjunct for surgical planning and intraoperative navigation. This clinical study was designed to evaluate the safety, efficacy, and accuracy of the Viewing Wand in a variety of intracranial procedures. METHODS: We used this system in 250 patients undergoing a wide range of neurosurgical procedures from July 1990 to July 1994, to assess its clinical usefulness and safety. In a subset of 45 neurosurgical patients studied between March 1993 and March 1994, a battery of objective accuracy measurements was obtained before and during surgery. RESULTS: In this series, there were no instances of adverse outcomes attributable to the use of this system. A comparison of two alternative patient-image registration techniques established that the fiducial-fit method was slightly more accurate than the surface-fit method (geometric means = 2.51 and 3.03 mm, respectively). The clinical accuracy achieved with magnetic resonance imaging was nearly equivalent to that with computed tomography. CONCLUSIONS: On the basis of this clinical series, recommendations are made regarding preoperative scanning parameters, registration techniques, and methods for reestablishing registration if needed during the course of surgery. The primary clinical benefits of the wand in this series were improved intraoperative navigation and surgical safety. For most cases, the wand was also useful in planning the location and size of the scalp incision, craniotomy, or corticotomy, as well as the extent of surgical resection.
17
Numerical recipes in C: the art of scientific computing
Choice Reviews Online · 1993 · 18.1K citations · Full text
Numerical recipes in Pascal: the art of scientific computing
Choice Reviews Online · 1990 · 11.9K citations
The Application Accuracy of Stereotactic Frames
Robert J. Maciunas, Robert L. Galloway, Jim Latimer · Neurosurgery · 1994 · 398 citations
A frameless, armless navigational system for computer-assisted neurosurgery
Amami Kato, Toshiki Yoshimine, Tõru Hayakawa et al. · Journal of neurosurgery · 1991 · 292 citations