Acta Oto-Laryngologica · 1989 · 42 citations · 15 references
Health ProfessionsAudiologyPhysiologyAcousticsAuditory ElectrophysiologyHearing ScienceAuditory ThresholdsCochlear FunctionCochlear NeuroscienceNoiseNoise ExposureNoise-induced Hearing DamageCochlear ElectrophysiologyCochlear PhysiologyNoise-induced Cochlear DamageNoise-induced Threshold ShiftOxygen Tension EffectsOxygen Tension MeasurementPure-tone ThresholdsSound Exposure Effects
The oxygen tension (pO2) of endolymph of the guinea pig cochlea was measured during exposure to loud sound (12 kHz or high-pass noise; 110 dB SPL up to 1 h duration). A small, but significant, steady decline in mean pO2 was observed after both pure tone and high-pass noise exposure. The extent of the change in pO2 varied from 0-50% in individual animals, compared with unexposed control animals. All exposed animals had an extensive loss of compound action potential (CAP) thresholds at frequencies of 8-30 kHz. However, there was no relationship between the extent of the change in pO2 of endolymph and CAP threshold loss.
15
A microelectrode for measuring intracellular PO2.
W. J. Whalen, J Riley, P. Nair · Journal of Applied Physiology · 1967 · 222 citations