High power switches at the Center for Electromechanics at the University of Texas at Austin

R.L. Sledge, Dallas Perkins, B. Rech

IEEE Transactions on Magnetics · 1989 · 17 citations · 1 references

Concepts

Abstract

Three high coulomb explosively actuated opening switches which have demonstrated reliability and fast switching in railgun experiments are presented. Two of these switches first provide a low conductivity path to transfer energy from homopolar generators to inductive energy stores and then open to commutate current to the railgun. One is a monolithic aluminum element with machined stress concentrations, and the other uses reloadable cartridges mechanically clamped. The third switch is designed to interrupt current in a compulsator powered railgun experiment. In the event of a short circuit fault, the switch automatically opens in order to prevent overheating of the compulsator armature windings. The design and excellent performance of these switches are reviewed.< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">&gt;</ETX>

References

1