EngineeringMechanical EngineeringHeat PipeThermoplastic CompositePolymer TechnologyPolymer Heat PipesMechanicsMaterials FabricationPolymer ProcessingRheologyPolymer CompositesPolyethylene LayersMaterials ScienceHeat TransferFlexible ElectronicsPolymer ScienceThermal EngineeringPolymer ModelingThermal Insulation
Flat, flexible, lightweight, polymer heat pipes (FPHP) were fabricated. The overall geometry of the heat pipe was 130 mm × 70 mm × 1.31 mm. A commercially available low-cost film composed of laminated sheets of low-density polyethylene terephthalate, aluminum and polyethylene layers was used as the casing. A triple-layer sintered copper woven mesh served as a liquid wicking structure, and water was the working fluid. A coarse nylon woven mesh provided space for vapor transport and mechanical rigidity. Thermal power ranging from 5 to 30 W was supplied to the evaporator while the device was flexed at 0°, 45° and 90°. The thermal resistance of the FPHP ranged from 1.2 to 3.0 K W−1 depending on the operating conditions while the thermal resistance for a similar-sized solid copper reference was a constant at 4.6 K W−1. With 25 W power input, the thermal resistance of the liquid–vapor core of the FPHP was 23% of a copper reference sample with identical laminated polymer material. This work shows a promising combination of technologies that has the potential to usher in a new generation of highly flexible, lightweight, low-cost, high-performance thermal management solutions.