Publication | Closed Access
Auditory Responses in Cochlear Implant Users With and Without GJB2 Deafness
47
Citations
16
References
2006
Year
Results suggest more consistent spiral ganglion survival along the length of the cochlea in GJB2-related HL as compared with non-GJB2-related HL, which appears to involve a decreasing gradient of spiral ganglion survival from the apex to the base of the cochlea. Our findings support our premise that in GJB2-related HL, dysfunction of gap junctions likely occurs to a similar degree in the apical and basal regions of the cochlea. This knowledge might be used to customize implantable devices for patients with HL in the future.