Publication | Closed Access
Void Fraction and Pressure Drop in a Water Electrolysis Cell
12
Citations
0
References
1970
Year
ElectrohydrodynamicsEngineeringEnergy EfficiencyElectrodialysisGas-liquid FlowChemical EngineeringFluid PropertiesElectrolyzer CellTransport PhenomenaPressure DropWater Electrolysis CellsElectrical EngineeringWater Electrolysis CellHeat TransferElectrochemistryWater ElectrolysisSlip RatioThermal EngineeringElectrolysis Of Water
An experimental investigation was conducted to determine the void fraction and pressure drop occurring in a forced-convection water electrolysis cell. It was concluded that the slip ratio is essentially unity for water electrolysis cells operating at atmospheric pressure and 80–100 deg F. A frictional pressure-drop multiplier was determined by a data reduction technique that has been used extensively in the boiling heat transfer literature. This multiplier has been correlated and found to be a function of both the void fraction and the gas generation rate.