Journal of Nuclear Science and Technology · 1983 · 32 citations · 3 references
EngineeringPhysicsRadiologyDiagnostic ImagingDiagnostic RadiologyFluid DynamicsComputed TomographyFlow MeasurementFlow MetrologyScanning TechniquesTwo-phase FlowVoid FractionCross-sectional Void FractionTime-averaged Void FractionTwo-phase Flow Void FractionVoid Fraction DistributionVoid Fraction FluctuationsVoid Fraction MeasurementVoid Fraction ProfilesVolumetric Reconstruction
Preliminary studies are made in order to apply an X-ray CT scanner to the measurement of cross-sectional distributions of void fractions in steady state two-phase flows. Using air-water flows in a horizontal U-shaped tube, results of CT scanner measurements are compared with those of the volumetric measurements with quick-closing valves and of hotfilm anemometer measurements. Studied are cross-sectionally averaged void fractions and void fraction profiles. The comparisons give good agreements. The effect of density fluctuations on the reconstruction of void fraction distributions in two-phase flows is also discussed. Consideration of the statistical fluctuation in the projection data for a stationary object gives the sufficient conditions required for the evaluation of the cross-sectional distribution of the scanning time-averaged void fraction in steady state two-phase flows.
3
The Fourier reconstruction of a head section
L. A. Shepp, B. F. Logan · IEEE Transactions on Nuclear Science · 1974 · 2.2K citations