Surfactant/Cement Blends Improve Plugging Operations in Oil-Base Muds

C.A. Harder, R.B. Carpenter, W. N. Wilson, E. R. Freeman, Henry Fleming Payne

1992 · 20 citations · 2 references

Concepts

Abstract

ABSTRACT Achieving a competent kick-off plug can be a difficult task, especially when cementing in oil-base mud (OBM). Historically, kick-off operations in OBM have required numerous costly and time consuming attempts to establish a good plug. Portland or hydraulic cements require water wetting of their chemical components to initiate and maintain the hydration process. If the hydration process is interrupted, so is strength development. OBM impedes cement hydration by oil-wetting the cement components. Laboratory testing indicates as little as 10% by volume OBM mixed with cement can dramatically affect cement thickening time and compressive strength (see Figure 1 and Figure 2). Cements mixed with water-wetting surfactants have significantly improved plug success rates in an area where plug failures in OBM were commonplace. The water wetting surfactant used in these tests effectively reduced the OBM contamination. Compressive strength, thickening time, and rheological testing have shown surfactant/cement blends to be more tolerant of OBM contamination (see Table 1). In field tests, using surfactant cements, only one attempt was required to establish a competent kick-off plug. In a three well program, a $2000 surfactant expenditure produced a projected $300,000 savings.

References

2