Applied Physics Letters · 1996 · 62 citations · 0 references
EngineeringMaterials EngineeringMaterials ScienceBiomedical ImagingDiagnostic ImagingDigital ImagingRadiation Imaging SystemsRadiographic ImagingScanning TechniquesX-ray DetectionX-ray DetectorsX-ray OpticsMicrofocus X-ray SourcesObjectsProjectionsRadiographic EquipmentReconstruction AlgorithmsSliceX-ray Imaging Physics
The method uses only object translation while keeping the x‑ray source and detector stationary, reconstructing cross sections from projections taken during motion with standard algorithms. The system enables inspection of large or flat objects with approximately 50 µm slice resolution, independent of size, using a microfocus x‑ray tube and line detector.
We have developed a computed laminography system for the inspection of large or flat objects using x rays. By this new laminographic method only a translation of the object is necessary. Both the x-ray source and the detector remain stationary. Object cross sections are reconstructed from digital projections taken during the object motions and for the reconstruction well-known algorithms are used. By use of a microfocus x-ray tube and a line detector, objects can be inspected with a slice resolution of about 50 μm independent of the object size.