Electroanalysis · 2001 · 33 citations · 14 references
Natural SciencesChemical EngineeringChemistryAnalytical ChemistryElectroanalytical MethodsElectrochemistryElectroanalytical ChemistryElectrochemical DetectionElectrode KineticsElectrode MaterialsEnvironmental Analytical ChemistryIon-selective ElectrodesCarbon ElectrodesCarbon-based Electrode MaterialsCarbon-based ElectrodesChitosanElectrochemical BehaviorElectrochemical MeasurementsGlassy Carbon ElectrodesMethod Detection Limit
Chitosan-modified carbon glassy electrode (CMGCE) was used for the determination of Br− for the first time. The measurement was carried out by cathodic stripping voltammetry. The effects of several experimental parameters, such as pH, the amount of modifier, deposition potential, deposition time were studied for analytical application. We also studied the adsorption isothermal line of bromide. A linear response was obtained in the concentration range 3.2×10−6–6.4×10−5 g/mL of Br−. The detection limit was found to be 9.6×10−7 g/mL. The method was used to detect bromide content in cetytrimethylammonium bromide (CTMAB), tetrabutyl ammonium bromide (TAB) and wastewater, the results are satisfactory.
14