Development and characterization of a neutron tomography system for a Research Reactor

Waleed Abd el Bar, Imbaby I. Mahmoud, Hussein A. Konber

Journal of Taibah University for Science · 2015 · 11 citations · 2 references

DOIFull text

Open access

Concepts

Abstract

Neutron tomography is a very powerful technique for the nondestructive evaluation of heavy industrial components as well as for soft hydrogenous materials enclosed in heavy metals, which are usually difficult to image using X-rays. It has found a variety of applications in medicine, agriculture and other heavy industries. In our effort to use this technique for non-destructive testing, a process has begun to upgrade the neutron radiography facility from static-based film (Nitrocellulose film and Agfa Structurix D7 photographic film) neutron radiography into a dynamic neutron radiography/tomography system by using scintillation screens (ZnS (Ag)-6LiF) and a CCD-camera.

References

2