Medicine & Science in Sports & Exercise · 2004 · 140 citations · 25 references
EducationKinesiologyPhysiologyExercise PhysiologyExercise TestingPhysical ActivityCardiopulmonary Exercise TestingEnergy ExpenditureEnergy Expenditure EstimationPhysical FitnessPhysical Fitness AssessmentTreadmill Exercise TestingEnergy Expenditure AnalysisEnergy Expenditure During ExerciseEnergy Expenditure MonitoringEnergy Expenditure Response To ExerciseExercise Heart Rate MonitoringHeart Rate MeasurementMetabolic Cost AssessmentMetabolic Rate Estimation
PURPOSE: The purpose of this study was to examine the accuracy of the Polar S410 for estimating gross energy expenditure (EE) during exercise when using both predicted and measured VO2max and HRmax versus indirect calorimetry (IC). METHODS: Ten males and 10 females initially had their VO2max and HRmax predicted by the S410, and then performed a maximal treadmill test to determine their actual values. The participants then performed three submaximal exercise tests at RPE of 3, 5, and 7 on a treadmill, cycle, and rowing ergometer for a total of nine submaximal bouts. For all submaximal testing, the participant had two S410 heart rate monitors simultaneously collecting data: one heart rate monitor (PHRM) utilized their predicted VO2max and HRmax, and one heart rate monitor (AHRM) used their actual values. Simultaneously, EE was measured by IC. RESULTS: In males, there were no differences in EE among the mean values for the AHRM, PHRM, and IC for any exercise mode (P > 0.05). In females, the PHRM significantly overestimated mean EE on the treadmill (by 2.4 kcal x min(-1)), cycle (by 2.9 kcal x min(-1)), and rower (by 1.9 kcal x min(-1)) (all P < 0.05). The AHRM for females significantly improved the estimation of mean EE for all exercise modes, but it still overestimated mean EE on the treadmill (by 0.6 kcal x min(-1)) and cycle (by 1.2 kcal x min(-1)) (P < 0.05). CONCLUSION: When the predicted values of VO2max and HRmax are used, the Polar S410 HRM provides a rough estimate of EE during running, rowing, and cycling. Using the actual values for VO2max and HRmax reduced the individual error scores for both genders, but in females the mean EE was still overestimated by 12%.
25
A H BECKETT, M ROWLAND, P TURNER · The Lancet · 1965 · 16.9K citations
Criteria for maximal oxygen uptake
Edward T. Howley, David R. Bassett, H Welch · Medicine & Science in Sports & Exercise · 1995 · 1.6K citations
Education, Kinesiology, Physiology +17
A category-ratio perceived exertion scale
B. Noble, Gunnar Borg, Ira Jacobs et al. · Medicine & Science in Sports & Exercise · 1983 · 625 citations
Education, Kinesiology, Physiology +16