Journal of Geotechnical and Geoenvironmental Engineering · 2010 · 68 citations · 17 references
EngineeringCivil EngineeringGeotechnical EngineeringSlope StabilitySoil MechanicsEarth ReinforcementEarth Retaining StructuresFoundation StabilityRetaining WallsSlope ReinforcementSlope StabilizationMechanically Stabilized Earth StructuresMechanically Stabilized Earth WallsMse Wall DesignMse WallsPerformance MonitoringRetaining Wall ConstructionWall DesignWall-soil Interaction
The expansion of Seattle‑Tacoma International Airport required a third runway, prompting the construction of a very tall mechanically stabilized earth wall to raise the grade. The study examines design challenges, instrumentation strategies, and performance outcomes of the MSE wall. A 46‑m‑tall, four‑tier MSE wall was built using 2H:1V fill slopes where possible and MSE retaining walls to protect wetlands, with performance monitored via strain gauges, inclinometers, optical surveys, and piezometers. Monitoring indicates the MSE wall performed satisfactorily and matched predicted behavior.
This paper focuses on the design and performance of a very tall mechanically stabilized earth (MSE) wall. Expansion of Seattle-Tacoma International Airport called for the construction of a third runway west of the two existing runways. A significant volume of compacted earth fill was required to raise the grade as much as 50 m to meet the level of the existing airfield. Nominal 2H:1V fill slopes were used where possible, but MSE retaining walls were used where fill slopes would have encroached into existing wetlands. Consequently a four-tier 46-m-tall MSE wall was constructed along a portion of the western edge of the embankment. Performance monitoring included strain gauge-instrumented reinforcing strips, inclinometer installations with sondex settlement rings, optical survey of the wall facing for vertical and lateral movements, and piezometers. This paper describes wall design issues, aspects associated with the instrumentation of the wall, and the observed performance. Monitoring indicates satisfactory performance of the MSE wall and compares reasonably well with predicted performance.
17