Acta Orthopaedica Scandinavica · 1991 · 108 citations · 16 references
MedicineOrthopaedic SurgeryOrthopedic SurgeryBone GraftingJoint Replacement SurgeryThermal AnalysisBone CementsHip ArthroplastyJoint Replacement MaterialsTemperature ManagementTemperature RegulationCuring ConditionsHigh-temperature CementingLow-temperature CementingPostoperative Temperature ManagementRevision Arthroplasty CementationTemperature Effects On CementingThermal Effects During Curing
The temperature was measured using thermocouples in the bone-cement interface during cement curing in 30 total hip replacement operations. A modern technique was used, including lavage and precooled vacuum-mixed cement. The mean maximum temperature in the acetabulum was 43 (38-52) degrees C and in the femur 40 (29-56) degrees C. The use of a precooled femoral prosthesis did not affect the peak temperature.
16
Bone cement, thermal injury and the radiolucent zone
Bengt Mjöberg, Holger Pettersson, R Rosenqvist et al. · Acta Orthopaedica Scandinavica · 1984 · 221 citations · Full text