PubMed · 1985 · 24 citations · 0 references
MedicineOrthopaedic SurgeryOrthopedic SurgeryDiagnostic ImagingDiagnostic RadiologyInterventional RadiologyCervical ImagingFluoroscopy-guided ProceduresContrastFacet Joint AssessmentFacet Joint ImagingFluoroscopic GuidanceInfiltrationJoint ArthrographyPosterior Approach
We describe a technique for cervical facet joint arthrography; a posterior approach is used. The patient is positioned prone, the neck flexed maximally, and the head turned 60-90 degrees opposite to the side of injection. The x-ray tube is angled cephalad in order to obtain a true tangent to the facet joint. The needle is inserted using fluoroscopic control in a direction parallel to the x-ray beam. Before the therapeutic infiltration, the intraarticular position of the needle is confirmed by injecting 0.3 ml of contrast medium.