Solid Vapor Pressure and Enthalpy of Sublimation for Perfluorooctanoic Acid

Catherine A. Barton, Miguel A. Botelho, Mary A. Kaiser

Journal of Chemical & Engineering Data · 2008 · 24 citations · 6 references

Concepts

Abstract

A modified gas saturation method was used to determine the solid vapor pressure of perfluorooctanoic acid (PFOA) at ambient temperatures. Measurements were made over the temperature range from (25 to 45) °C. Pressures ranged from (5.2 to 40.7) Pa. The enthalpy of sublimation was calculated as 88.9 kJ·mol −1 .