Clinical Orthopaedics and Related Research · 2012 · 37 citations · 44 references
MedicineOrthopaedic SurgeryOrthopedic SurgeryJoint Replacement SurgeryOrthopedic BiomechanicsOrthopedicsArthroplasty BiomechanicsHip ArthroplastyHip BiomechanicsJoint Motion AnalysisJoint StabilityDislocation After Hip ArthroplastyDislocation RiskFemoral Component PositioningHip Joint StabilityHip PositioningThree-dimensional KinematicsThree-dimensional Stability AnalysisTotal Hip Arthroplasty Biomechanics
BACKGROUND: Dislocation remains common after total hip arthroplasty. Efforts have been made to identify and minimize risk factors. One such factor, jump distance, or the distance the femoral head must travel before dislocating, has been poorly characterized with respect to three-dimensional kinematics. QUESTIONS/PURPOSES: We therefore determined: (1) the three-dimensional stability of four different component designs; (2) whether the degree of abduction and anteversion affects the stability; (3) whether pelvic inclination angles affected stability; and (4) which combination of these three factors had the greatest stability. METHODS: We created a positionable three-dimensional model of a THA. Acetabular components were modeled in various abduction and anteversion angles and in two different pelvic inclinations which simulate standing and chair-rising activities. RESULTS: The posterior horizontal dislocation distance increased as inclination angle and femoral head size increased. The 48-mm resurfacing typically had lower jump distances and was at risk of posterior edge loading at 30° inclination. The highest jump distance for all positions and activities occurred with the dual-mobility bearing. CONCLUSION: These findings suggest that monoblock cups require extremely accurate positioning for low dislocation risk and that pelvic orientation may increase dislocation risks. CLINICAL RELEVANCE: As a result of the dual-mobility designs having the greatest resistance to dislocation, these cups may be appropriate for patients who are at risk for dislocation in difficult primary situations and in revision hip arthroplasty procedures in which proper component orientation may be less likely to be achieved.
44
Dislocations after total hip-replacement arthroplasties.
G E Lewinnek, J L Lewis, R Tarr et al. · Journal of Bone and Joint Surgery · 1978 · 2.8K citations
Dislocations After Total Hip-Replacement Arthroplasties
Paul A. Banaszkiewicz · 2013 · 2.1K citations
The Epidemiology of Revision Total Hip Arthroplasty in the United States
Kevin J. Bozic, Steven M. Kurtz, Edmund Lau et al. · The Journal of Arthroplasty · 2009 · 1.3K citations
Darryl D. DʼLima, Andrew G. Urquhart, Knute O. Buehler et al. · Journal of Bone and Joint Surgery · 2000 · 540 citations
Roel De Haan, Christophe Pattyn, H.S. Gill et al. · Journal of Bone and Joint Surgery - British Volume · 2008 · 519 citations · Full text