Contrast-Enhanced Whole-Heart MR Coronary Angiography at 3.0 T Using the Intravascular Contrast Agent Gadofosveset

Maria Prompona, Clemens C. Cyran, Konstantin Nikolaou, Kerstin Bauner, Maximilian F. Reiser, Armin Huber

Investigative Radiology · 2009 · 49 citations · 32 references

Concepts

Abstract

OBJECTIVES: The purpose of this study was to compare contrast-enhanced (CE) whole-heart coronary magnetic resonance angiography (MRA) at 3.0 T using gadofosveset to noncontrast-enhanced steady-state free precession (SSFP) coronary MRA at 1.5 T. MATERIALS AND METHODS: A prospective randomized study was conducted among 20 healthy male volunteers. The same group of subjects underwent CE whole heart MRA at 3.0 T employing a 3D FLASH sequence with IR prepulse after gadofosveset injection as well as noncontrast-enhanced coronary MRA at 1.5 T using a 3D SSFP sequence with T2-preparation. Both techniques were performed using prospective ECG-triggering and adaptive respiratory gating. Acquisition time, signal-to-noise ratio of coronary blood, contrast-to-noise ratio (CNR) between coronaries and adjacent myocardium or epicardial fat, and image quality were evaluated in each case. RESULTS: A significant increase of the overall CNR between coronary blood and adjacent myocardium was measured on images acquired at 3 T in comparison to 1.5 T. The mean values were 38.9 +/- 19.6 and 26.3 +/- 15.4, respectively (P[r] < 0.005). There was no significant difference in CNR between coronary blood and epicardial fat. The mean image quality for the proximal and mid coronary segments was not statistically different between 1.5 T and 3.0 T (P > 0.05), however, the distal coronary segments were rated significantly higher for the CE MRA at 3.0 T (P = 0.02). The average acquisition time (15.29 +/- 5.73 minutes at 1.5 T vs. 17.29 +/- 5.18 minutes at 3 T) and overall image quality (2.15 +/- 0.49 at 1.5 T vs. 2.35 +/- 0.39 at 3 T) were similar for both methods. CONCLUSIONS: CE whole-heart coronary MRA at 3.0 T demonstrated higher overall CNR between coronary blood and myocardium and an improved image quality of the distal coronary segments compared with noncontrast-enhanced SSFP coronary MRA at 1.5 T.

References

32

ACC/AHA guidelines for coronary angiography11“ACC/AHA Guidelines for Coronary Angiography” was approved by the American College of Cardiology Board of Trustees in October 1998 and by the American Heart Association Science Advisory and Coordinating Committee in December 1998.22When citing this document, the American College of Cardiology and the American Heart Association request that the following format be used: Scanlon PJ, Faxon DP, Audet AM, Carabello B, Dehmer GJ, Eagle KA, Legako RD, Leon DF, Murray JA, Nissen SD, Pepine CJ, Watson RM. ACC/AHA guidelines for coronary angiography: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Committee on Coronary Angiography). J Am Coll Cardiol1999;33:1756–82433This document is available on the websites of the ACC (www.acc.org) and the AHA (www.americanheart.org). Reprints of this document (the complete guidelines) are available for $5 each by calling 800-253-4636 (US only) or writing the American College of Cardiology, Educational Services, 9111 Old Georgetown Road, Bethesda, MD 20814-1699. Ask for reprint No. 71-0164. To obtain a reprint of the shorter version (executive summary and summary of recommendations) published in the May 4, 1999, issue of Circulation, ask for reprint No. 71-0163. To purchase additional reprints (specify version and reprint number): up to 999 copies, call 800-611-6083 (US only) or fax 413-665-2671; 1000 or more copies, call 214-706-1466, fax 214-691-6342, or e-mail pubauth@heart.org

Patrick J. Scanlon, David P. Faxon, Anne-Marie Audet et al. · Journal of the American College of Cardiology · 1999 · 1.1K citations

, , +10