Concepedia

Publication | Open Access

Modified mesh for hernia repair that is adapted to the physiology of the abdominal wall

259

Citations

0

References

2002

Year

Abstract

Different meshes caused specific histological reactions with changes of their mechanical properties after implantation in rodents. A new mesh with a reduced amount of polypropylene showed both less inflammation and less restriction in the mobility of the abdominal wall though it exceeded the required tensile strength of 16 N/cm.