Acta Oto-Laryngologica · 1977 · 49 citations · 10 references
MedicineAudiologyOtolaryngologyHearing AssessmentHearing ScienceOtologyAudiologic EvaluationEar SurgeryNoise-induced Hearing DamageOtologic SurgeryTemporal Bone SurgeryTemporary Threshold ShiftAudiometric Threshold ShiftChronic Otitis Media SurgeryIntraoperative Threshold Shift DetectionNoise-induced Temporary Threshold ShiftNoise-induced Threshold ShiftPostoperative Threshold ShiftPreoperative Hearing AssessmentSensorineural Hearing Loss Effects
TTS resulting from drilling in the temporal bone was detected by means of pre- and post-exposure ECoG recordings taken during ear surgery for chronic otitis media. The TTS obtained varied between 5 and 40 dB at 4 and 8 kHz. The correlation between duration of noise exposure and magnitude of TTS was statistically significant. The results indicate that drill-induced noise in ear surgery may result in postoperative high-tone sensorineural hearing loss, and support the view that manipulation of the ossicular chain during ear surgery causes mainly a threshold shift at the lower frequencies.
10
Principles of electric response audiometry.
Hallowell Davis · PubMed · 1976 · 326 citations
James D. Miller · The Journal of the Acoustical Society of America · 1974 · 229 citations
Drill-Generated Noise Levels in ear Surgery
P. Kylén, Stig Arlinger · Acta Oto-Laryngologica · 1976 · 89 citations
Medicine, Otolaryngology, Surgery +11
Acoustic trauma of the cochlea from ear surgery
Harold F. Schuknecht, Juergen Tonndorf · The Laryngoscope · 1960 · 84 citations
Medicine, Otolaryngology, Surgery +14