Journal of Instrumentation · 2013 · 43 citations · 20 references
EngineeringNuclear EngineeringRadiation DetectionRadiation MeasurementThin FilmsDetector TechnologyGamma-ray DetectionGamma-ray DetectorsNeutron DetectionRadiation DetectorsArea CoverageDetectorsGas Proportional CountersNeutron Detector SystemsNeutron DetectorsSolid-state Neutron DetectorsThermal Neutron DetectionThin-film Detectors
Currently, many detector technologies for thermal neutron detection are in development in order to lower the demand for the rare He-3 gas. Gas detectors with solid thin film neutron converters readout by gas proportional counter method have been proposed as an appropriate choice for applications where large area coverage is necessary. In this paper, we investigate the probability for gamma-rays to generate a false count in a neutron measurement. Simulated results are compared to measurement with B-10 thin film prototypes and a He-3 detector. It is demonstrated that equal gamma-ray rejection to that of He-3 tubes is achieved with the new technology. The arguments and results presented here are also applicable to gas detectors with converters other than solid B-10 layers, such as Li-6 layers and (BF3)-B-10 gas.
20
FIGARO: The new horizontal neutron reflectometer at the ILL
Richard A. Campbell, Hanna Wacklin, Iain Sutton et al. · The European Physical Journal Plus · 2011 · 258 citations
D17: the new reflectometer at the ILL
R. Cubitt, Giovanna Fragneto · Applied Physics A · 2002 · 221 citations
B4C thin films for neutron detection
Carina Höglund, Jens Birch, K.H. Andersen et al. · Journal of Applied Physics · 2012 · 159 citations · Full text