Circulation · 1998 · 131 citations · 26 references
MedicineCardiologyBiomedical ImagingDiagnostic ImagingUltrasonographyCardiac ImagingCardiovascular ImagingContrast-enhanced UltrasoundIntravascular ImagingMyocardial Blood Flow QuantificationMyocardial Perfusion ImagingBlood FlowCardiac Myocardial Perfusion ImagingIntracardiac EchocardiographyMicrobubble Contrast ImagingQuantitative Cardiac ImagingQuantitative Myocardial Perfusion ImagingReplenishmentRest Myocardial Perfusion Imaging
BACKGROUND: We hypothesized that by using our newly defined method of destroying microbubbles and measuring their rate of tissue replenishment, we could assess the transmural distribution of myocardial perfusion. METHODS AND RESULTS: We studied 12 dogs before and after creation of left anterior descending coronary artery stenoses both at rest and during hyperemia (n=62 stages). Microbubbles were administered as a constant infusion, and myocardial contrast echocardiography (MCE) was performed with the use of different pulsing intervals. The video intensity versus pulsing interval plots derived from each myocardial pixel were fitted to an exponential function: y=A(1-ebetat), where A reflects microvascular cross-sectional area (or myocardial blood volume), and beta reflects mean myocardial microbubble velocity. The product A . beta represents myocardial blood flow (MBF). Average values for these parameters were derived from the endocardial and epicardial regions of interest placed over the left anterior descending coronary artery bed. Radiolabeled microsphere-derived MBF was also measured from the same regions. There was poor correlation between radiolabeled microsphere-derived MBF and A-endocardial/epicardial ratios (EER) (r=0.46). The correlation with beta-EER was better (r=0. 69, P<0.01). The best correlation with radiolabeled microsphere-derived MBF-EER was noted with A . beta-EER (r=0.88, P<0. 01). CONCLUSIONS: The transmural distribution of myocardial perfusion can be accurately assessed with MCE with the use of our newly described method of tissue replenishment of microbubbles after their ultrasound-induced destruction. In the model studied, an uncoupling of the transmural distribution of MBF and myocardial blood volume was observed during reversal of the MBF-EER.
26
Blood flow measurements with radionuclide-labeled particles
Michaël Heymann, B. Payne, Julien I.E. Hoffman et al. · Progress in Cardiovascular Diseases · 1977 · 2.1K citations
Control of Coronary Blood Flow by an Autoregulatory Mechanism
Paul Mosher, John Ross, PATRICIA ANN MCFATE et al. · Circulation Research · 1964 · 382 citations · Full text
Medicine, Cardiology, Physiology +15
Ananda R. Jayaweera, Nathaniel Edwards, William P. Glasheen et al. · Circulation Research · 1994 · 258 citations
Medicine, Cardiology, Physiology +17