Early construction and operation of highly contaminated water treatment system in Fukushima Daiichi Nuclear Power Station (I) – Ion exchange properties of KURION herschelite in simulating contaminated water

Takeshi Tsukada, Koichi Uozumi, Takatoshi Hijikata, Tadafumi Koyama, Keiji Ishikawa, Shoichi Ono, Shunichi Suzuki, Mark S. Denton, R. Keenan, Gaëtan Bonhomme

Journal of Nuclear Science and Technology · 2014 · 27 citations · 1 references

DOIFull text

Open access

Concepts

Abstract

To support the design and operation of the decontamination system using KURION media for the treatment of highly contaminated water accumulated in Fukushima Daiichi Nuclear Power Station, Central Research Institute of Electric Power Industry has urgently carried out many kinds of research and development programs to support the operation of the decontamination system using columns filled with three kinds of KURION media (H, AGH and SMZ). Since the contaminated water at Fukushima Daiichi Nuclear Power Station contained seawater and oil, the effects of sea salt and dissolved oil on Cs adsorption behavior were examined closely by batch type. The concentration of sea salt in the solutions was varied between 0.0 and 3.4 wt%. The Cs adsorption capacity of KURION herschelite in seawater decreased to nearly 1/10th of that in pure water, but it was still concluded that herschelite has sufficient adsorption capacity to remove Cs from the contaminated water. The effect of dissolved oil could be ignored because of its low solubility in seawater. Langmuir-type adsorption isotherm equations, which can be applied for estimating Cs adsorption in sea salt containing water, were developed.

References