Offshore Technology Conference · 1989 · 15 citations · 0 references
EngineeringCivil EngineeringGeotechnical EngineeringOffshore EngineeringOffshore StructuresConnection DesignOffshore Facilities DesignOffshore FoundationsOffshore Installation EngineeringStructural ConnectionsStructural DesignFixed Offshore PlatformsFixed Offshore Structure DesignStructural Analysis Of Offshore Platforms
ABSTRACT DnV's new Rules for Fixed Offshore Installations (draft) has replaced previous parametric formulae for the strength of grouted connection with equations based on a physical interpretation of the strength of grouted connections. The paper gives the background for the equations. It also explains the background for the safety factors adopted. The design formulae apply to pile sleeve connections, bolted clamps prestressed clamps and other related connections. INTRODUCTION DnV has recently completed the development of a new set of Rules for Fixed Offshore Installations. The new rules cover both steel and concrete structures as well as production and utility systems and equipment. It stipulates requirements for the design, construction, installation and operation. Giving ample time for overlap, it is the intention that this new code will replace DnV's "Rules for the Design and Construction of Fixed Offshore Structures"2 which was published in 1977. The development of the new code principally aims; at incorporating recent developments in various technical areas. Grouted tubular steel connections which are typically used for in situ application is such an area. The most common applications are as pile sleeve connections, as site joints and as repair clamps. Axial force is a principal load for this type of connection. Traditionally code provisions have implicitly assumed that the forces in such connections are transferred by cohesion or adhesion between the grout and the steel. Code provisions have ranged from a simple specification of a value for the permissible interface shear stress to more complex parametric formulae of empirical derivation. The bulk of test data was obtained as recently as about ten years ago. Experience of the performance of grouted connections has largely been related to applications with low interface shear stresses in earlier times. Only in recent years have we seen extensive use of grouted connections with a high utilization of their structural capacity. The present generation of design codes have therefore included appropriately high margins of safety in their provisions for design of grouted connections. The 1977 edition of DnV's "Rules" for the Design and Construction of Fixed Offshore Structures" 2 incorporated a new safety format and safety margins which had been the subject of extensive study. It is therefore the intention to maintain the same safety format in the proposed new code. From being pictured in the mind of those involved as a material used to fill the gap between the chord and the pile, grouted construction is today being used to structurally reinstate and also to seal damaged pipelines. Today?s grouted clamps which may incorporate prestressing and liners may be designed using non linear finite element analysis. Grouted construction has in the past ten years developed greatly. It is therefore also appropriate that this is properly reflected in code provisions.