Journal of Environmental Science and Health Part A · 2012 · 114 citations · 23 references
EngineeringChemical EngineeringEnvironmental EngineeringEnvironmental ChemistryReaction EngineeringWastewater TreatmentChemical OxidationIndustrial Effluent TreatmentIndustrial Wastewater TreatmentPetroleum Hydrocarbon RemediationWastewater BiotreatmentWastewater ManagementAdvanced Oxidation ProcessesContinuous FlowFenton ReactionHydrocarbon OxidationOxidation ProcessesPhoto-fenton OxidationPhysicochemical TreatmentWastewater Treatment Processes
The objective of this study was to investigate the application of advanced oxidation processes (AOPs) to the treatment of wastewaters contaminated with hydrocarbon oil. Three different oil-contaminated wastewaters were examined and compared: (i) a 'real' hydrocarbon wastewater collected from an oil refinery (Conoco-Phillips Whitegate refinery, County Cork, Ireland); (ii) a 'real' hydrocarbon wastewater collected from a car-wash facility located at a petroleum filling station; and (iii) a 'synthetic' hydrocarbon wastewater generated by emulsifying diesel oil and water. The AOPs investigated were Fe(2+)/H(2)O(2) (Fenton's reagent), Fe(2+)/H(2)O(2)/UV (Photo-Fenton's reagent) which may be used as an alternative to, or in conjunction with, conventional treatment techniques. Laboratory-scale batch and continuous-flow experiments were undertaken. The photo-Fenton parametric concentrations to maximize COD removal were optimized: pH = 3, H(2)O(2) = 400 mg/L, and Fe(2+) = 40 mg/L. In the case of the oil-refinery wastewater, photo-Fenton treatment achieved approximately 50% COD removal and, when preceded by physicochemical treatment, the percentage removal increased to approximately 75%.
23