Journal of the Magnetics Society of Japan · 1998 · 13 citations · 2 references
EngineeringBiomedical EngineeringElectrical EngineeringBiosensorsMicroelectromechanical SystemsSensorsMechanical MeasurementMechanical SensorsMicroelectromechanical SensorsSoft SensorsStrain MeasurementStrain SensorsBiomedical Strain MonitoringLinearityMagnetization RotationMicroelectromechanical Strain SensorsMultivibrator CircuitsSoft Strain SensorsStrain Gauge MeasurementStrain Gauge Sensors
A highly sensitive linear strain gauge using a pair of amorphous CoSiB wires fixed to a plastic cantilever beam combined with a CMOS IC multivibrator circuit is presented. The wires are magnetized with a sharp pulse current to generate the stress impedance (SI) effect, showing a gauge factor of about 2000 in the CMOS IC circuit The linear strain gauge shows a resolution of about 2.5 mg for weight detection with high linearity in the range of −0.75∼1.25 g. The mechanism of the SI characteristics in the CoSiB wire is analyzed using a magnetization rotation model. Pulsation of fingertip blood vessels was stably detected by using the SI gauge stress sensor.
2
Magneto-impedance effect in amorphous wires
L.V. Panina, K. Mohri · Applied Physics Letters · 1994 · 1K citations