Haematologica · 2015 · 41 citations · 24 references
MedicineHematologyPathologyCellular PathologyDiagnostic PathologyHematopathologyBone Marrow EvaluationClinical HematologyFlow CytometryHematologic PathologyMyelodysplastic SyndromesMyeloproliferative NeoplasmsBone Marrow CytologyFlow Cytometric AnalysisFlow Cytometric Cell AnalysisFlow Cytometry ImmunophenotypingMultiparameter Flow CytometryMyelodysplastic Syndrome AssessmentMyeloid NeoplasmsMyeloproliferative Neoplasm Assessment
Although numerous recent publications have demonstrated interest in multiparameter flow cytometry in the investigation of myelodysplastic disorders, it is perceived by many laboratory hematologists as difficult and expensive, requiring a high level of expertise. We report a multicentric open real-life study aimed at evaluating the added value of the technically simple flow cytometry score described by the Ogata group for the diagnosis of myelodysplastic syndromes. A total of 652 patients were recruited prospectively in four different centers: 346 myelodysplastic syndromes, 53 myelodysplastic/myeloproliferative neoplasms, and 253 controls. The Ogata score was assessed using CD45 and CD34 staining, with the addition of CD10 and CD19. Moreover, labeling of CD5, CD7 and CD56 for the evaluation of myeloid progenitors and monocytes was tested on a subset of 294 patients. On the whole series, the specificity of Ogata score reached 89%. Respective sensitivities were 54% for low-risk myelodysplastic syndromes, 68% and 84% for type 1 and type 2 refractory anemia with excess of blasts, and 72% for myelodysplastic/myeloproliferative neoplasms. CD5 expression was poorly informative. When adding CD56 or CD7 labeling to the Ogata score, sensitivity rose to 66% for low-risk myelodysplastic syndromes, to 89% for myelodysplastic/myeloproliferative neoplasms and to 97% for refractory anemia with excess of blasts. This large multicenter study confirms the feasibility of Ogata scoring in routine flow cytometry diagnosis but highlights its poor sensitivity in low-risk myelodysplastic syndromes. The addition of CD7 and CD56 in flow cytometry panels improves the sensitivity but more sophisticated panels would be more informative.
24
Denise A. Wells, Martin Benesch, Michael R. Loken et al. · Blood · 2003 · 363 citations · Full text
Medicine, Cell Biology, Hematology +17
Diagnostic utility of flow cytometric immunophenotyping in myelodysplastic syndrome
Maryalice Stetler‐Stevenson, Diane C. Arthur, Nicholas Jabbour et al. · Blood · 2001 · 299 citations · Full text
Medicine, Hematology, Immunology +16