24th Structures, Structural Dynamics and Materials Conference · 1983 · 12 citations · 13 references
EngineeringMechanical EngineeringSystems EngineeringFinite Element AnalysisStructural AnalysisVibrationExperimental Modal TestingModal AnalysisModal TheoryStructural VibrationVibration AnalysisWind Turbine TechnologyFinite Element Modal AnalysisFree Vibration DecayModal IdentificationModal Parameter EstimationModal Parameter IdentificationModal TestingNatural Frequency IdentificationStructural Modal Identification
A new testing technique and the Ibrahim time-domain (ITD) modal identification algorithm have been combined, resulting in a capability to estimate modal parameters for rotating-blade systems. This capability has been evaluated on the Sandia two-meter, vertical-axis wind turbine. Variation in modal frequencies as a function of rotation speed has been experimentally determined from 0 rpm (parked) to 800 rpm. Excitation of the rotating turbine was provided by a scheme which suddenly released a pretensioned cable, thus plucking the turbine as it rotated. The structural response was obtained by passing the signals through slip rings. Using the measured free-decay responses as input data for the ITD algorithm, the modes of the rotating turbine were determined at seven rotation speeds. The measured modal parameters were compared with analytical results obtained from a finite element analysis and with experimental results obtained from a complex exponential identification algorithm.
13
Vibration of a rotating beam with tip mass
Suong V. Hoa · Journal of Sound and Vibration · 1979 · 199 citations
Engineering, Mechanical Engineering, Structural Dynamics +10