IEEE Transactions on Energy Conversion · 2014 · 41 citations · 24 references
EngineeringElectrical EngineeringCircuit TheoryElectric MachinesPower ElectronicsLosses In Electric MachinesMachine WindingsMagnetic Circuit AnalysisMagnetic ComponentsMultilevel ConvertersCore Loss AnalysisCore Loss ModelingCore LossesFinite Element SimulationIron LossesLoss AnalysisMagnetic CoresMagnetic Losses
The effect of multilevel inverter supply on power losses in magnetic cores and electrical machines is studied. A dynamic numerical model for the hysteresis, eddy current, and excess losses in a core lamination is first developed. By both measurements and simulations for a ring-core inductor, we demonstrate how increasing the number of inverter voltage levels decreases the iron losses when compared with traditional two-level supply. Although the switching frequency has a significant impact on the iron losses in the case of a traditional two-level inverter, using three or five voltage levels makes the losses almost independent of the switching. Finally, finite-element simulations show that similar reductions are also possible for the core losses of 150-kVA and 12.5-MW wound-field synchronous machines, in which rather low switching frequencies are typically used. Calorimetric loss measurements are also presented for the 150-kVA machine in order to confirm the significant effect of switching frequency on the core losses with two-level inverter supply.
24
The age of multilevel converters arrives
Leopoldo G. Franquelo, José Rodríguez, José I. Leon et al. · IEEE Industrial Electronics Magazine · 2008 · 2K citations · Full text
Farid Khoucha, M. S. Lagoun, Abdelaziz Kheloui et al. · IEEE Transactions on Energy Conversion · 2010 · 132 citations
Engineering, Electrical Engineering, Electric Vehicle Technology +16