Effect of Multilevel Inverter Supply on Core Losses in Magnetic Materials and Electrical Machines

Paavo Rasilo, Aboubakr Salem, Ahmed Abou‐Elyazied Abdallh, Frederik De Belie, Luc Dupré, Jan Melkebeek

IEEE Transactions on Energy Conversion · 2014 · 41 citations · 24 references

DOIFull text

Open access

Concepts

Abstract

The effect of multilevel inverter supply on power losses in magnetic cores and electrical machines is studied. A dynamic numerical model for the hysteresis, eddy current, and excess losses in a core lamination is first developed. By both measurements and simulations for a ring-core inductor, we demonstrate how increasing the number of inverter voltage levels decreases the iron losses when compared with traditional two-level supply. Although the switching frequency has a significant impact on the iron losses in the case of a traditional two-level inverter, using three or five voltage levels makes the losses almost independent of the switching. Finally, finite-element simulations show that similar reductions are also possible for the core losses of 150-kVA and 12.5-MW wound-field synchronous machines, in which rather low switching frequencies are typically used. Calorimetric loss measurements are also presented for the 150-kVA machine in order to confirm the significant effect of switching frequency on the core losses with two-level inverter supply.

References