Anesthesia & Analgesia · 1980 · 16 citations · 0 references
MedicineAnesthesiologySurgeryAnesthesiaGeneral AnesthesiaPulmonary Function TestingGas Exchange AssessmentHemodynamic Response To AnesthesiaCarbon DioxidePulmonary Gas ExchangePulmonary Gas TransferRespiratory Gas Exchange
Expired gas flow volume (VE), carbon dioxide excretion (Vco2) and oxygen consumption (Vo2) were measured continuously for 2-minute periods at 15-minute intervals during at least 75 minutes of general anesthesia and surgery in clinical patients. Analog tape-recorded outputs from an infrared CO2 analyzer, from a rapid polarographic O2 analyzer, and from a pneumotachograph were subsequently processed by a general purpose digital computer. Values for VE, VCO2, and VO2 in a group of 50 normal paralyzed endotracheally intubated women with balanced N2O-O2-fentanyl anesthesia for lower abdominal surgery compare favorably with the few published reports of similar measurements. The measured response to anesthesia and surgery in most patients included a progressive increase in O2 uptake and a concurrent but not necessarily simultaneous decrease in CO2 output with a consequent decreased respiratory gas exchange ratio (RE).