Real time sensor for monitoring oxygen in radio–frequency plasma applications

V. Milosavljević, Ronan Faulkner, M. B. Hopkins

Optics Express · 2007 · 10 citations · 0 references

DOIFull text

Open access

Concepts

Abstract

Real time closed loop control of plasma assisted semiconductor manufacturing processes has received significant attention in recent years. Therefore we have developed and tested a customized optical sensor based on buffer gas (argon) actinometry which has been used to determine relative densities of atomic and molecular oxygen in an Ar/O(2) radio-frequency ICP chamber. The operation and accuracy of our optical sensor compared favorably with a high resolution commercial spectrometer but at lower cost and exhibited improved actinometric performance over a low resolution commercial spectrometer. Furthermore, threshold tests have been performed on the validity of buffer gas based actinometry in Ar/O(2) ICP plasmas where Ar is no longer a trace gas through Xe actinometry. The plasma conditions for which this customized optical sensor can be used for closed loop control have been established.