Circulation · 2009 · 213 citations · 25 references
MedicineCardiologyNuclear MedicineBiomedical ImagingCardiac Nuclear MedicineDiagnostic Nuclear MedicineCardiac ImagingCardiac Nuclear ImagingMyocardial Blood Flow QuantificationMyocardial Perfusion ImagingPerfusion ImagingPositron Emission TomographyMyocardial Perfusion TracersMyocardial Tracer Uptake AssessmentMyocardial Uptake QuantificationNitrogen-13 Ammonia Perfusion ImagingPet TracersPharmacologic Stress Myocardial Perfusion ImagingRest Myocardial Perfusion ImagingStress
BACKGROUND: Positron-emission tomography (PET) tracers for myocardial perfusion are commonly labeled with short-lived isotopes that limit their widespread clinical use. 18F-BMS-747158-02 (18F-BMS) is a novel pyridaben derivative that was evaluated for assessment of myocardial perfusion by comparison with 13N-ammonia (13NH3) and with radioactive microspheres in a pig model. METHODS AND RESULTS: Fourteen pigs injected with 500 MBq of 13NH3 or 100 to 200 MBq of 18F-BMS underwent dynamic PET at rest and during pharmacological stress. In 8 of these pigs, 18F-BMS was injected during stress combined with transient, 2.5-minute constriction of the left anterior descending coronary artery. Radioactive microspheres were coinjected with 18F-BMS. Ratios of myocardial tracer uptake to surrounding tissues were determined, and myocardial blood flow was quantified by compartmental modeling. Both tracers showed high and homogeneous myocardial uptake. Compared with 13NH3, 18F-BMS showed higher activity ratios between myocardium and blood (rest 2.5 versus 4.1; stress 2.1 versus 5.8), liver (rest 1.2 versus 1.8; stress 0.7 versus 2.0), and lungs (rest 2.5 versus 4.2; stress 2.9 versus 6.4). Regional myocardial blood flow assessed with 18F-BMS PET showed good correlation (r=0.88, slope=0.84) and agreement (mean difference -0.10 [25th percentile -0.3, 75th percentile 0.1 mL x min(-1) x g(-1)]) with that measured with radioactive microspheres over a flow range from 0.1 to 3.0 mL x min(-1) x g(-1). The extent of defects induced by left anterior descending coronary artery constriction measured by 18F-BMS and microspheres also correlated closely (r=0.63, slope=1.1). CONCLUSIONS: 18F-BMS-747158-02 is a very attractive new PET perfusion tracer that allows quantitative assessment of regional myocardial perfusion over a wide flow range. The long half-life of 18F renders this tracer useful for clinical PET/CT applications in the workup of patients with suspected or proven coronary artery disease.
25
William H. Press, Saul A. Teukolsky, William T. Vetterling et al. · 1994 · 15.4K citations
Blood flow measurements with radionuclide-labeled particles
Michaël Heymann, B. Payne, Julien I.E. Hoffman et al. · Progress in Cardiovascular Diseases · 1977 · 2.1K citations
Gary D. Hutchins, Markus Schwaiger, Karen C. Rosenspire et al. · Journal of the American College of Cardiology · 1990 · 554 citations
Medicine, Cardiology, Radiology +17
Albert Schömig, Adnan Kastrati, Josef Dirschinger et al. · New England Journal of Medicine · 2000 · 478 citations · Full text