Cornea · 2006 · 15 citations · 9 references
MedicineOphthalmologySurgeryMicrosurgeryOcular TraumaOphthalmic SurgeryCorneal TransplantationCorneal TraumaCorneal Wound HealingPenetrating KeratoplastyRetinal DetachmentRetinal SurgeryDescemet Membrane DetachmentDescemet Membrane PathologyDescemet Membrane RuptureGraft DehiscenceNeed For Surgical InterventionPhysical Barrier DesignPhysical Barrier IntegrityRepeat Penetrating Keratoplasty
PURPOSE: To present a case of inadvertently retained Descemet Membrane (DM). METHODS: Case report. RESULTS: A 41-year-old male with previous history of retinal detachment surgery underwent a repeat penetrating keratoplasty; the first graft decompensated secondary to silicone oil. Postoperatively, an inadvertently retained DM was observed forming a physical barrier to the silicone oil. CONCLUSION: Retained DM is a rare complication of penetrating keratoplasty, with only a few cases reported in the literature. This membrane served a protective role from the effects of silicone oil on the donor cornea but later opacified and required surgical intervention.
9
The corneal endothelium. Normal and pathologic structure and function.
George O. Waring, William M. Bourne, Henry F. Edelhauser et al. · PubMed · 1982 · 600 citations
Medicine, Anatomy, Ophthalmology +14
George O. Waring, William M. Bourne, Henry F. Edelhauser et al. · Ophthalmology · 1982 · 464 citations