Medical Physics · 2007 · 51 citations · 50 references
EngineeringBiomedical EngineeringRadiologyDiagnostic ImagingRadiation DetectionSensorsCmos Circuit DesignDetector TechnologyRadiation Imaging DetectorsRadiographic ImagingX-ray DetectionX-ray DetectorsComplementary Metal-oxide-semiconductor Detector SensitivityComplementary Metal-oxide-semiconductor DetectorsComplementary Metal-oxide-semiconductor SensorsModulation Transfer FunctionPhosphorsRead NoiseShot NoiseX-ray Imaging Performance
Monolithic complementary metal oxide semiconductor (CMOS) active pixel sensors with high performance have gained attention in the last few years in many scientific and space applications. In order to evaluate the increasing capabilities of this technology, in particular where low dose high resolution x-ray medical imaging is required, critical electro-optical and physical x-ray performance evaluation was determined. The electro-optical performance includes read noise, full well capacity, interacting quantum efficiency, and pixels cross talk. The x-ray performance, including x-ray sensitivity, modulation transfer function, noise power spectrum, and detection quantum efficiency, has been evaluated in the mammographic energy range. The sensor is a 525 x 525 standard three transistor CMOS active pixel sensor array with more than 75% fill factor and 25 x 25 microm pixel pitch. Reading at 10 f/s, it is found that the sensor has 114 electrons total additive noise, 10(5) electrons full well capacity with shot noise limited operation, and 34% interacting quantum efficiency at 530 nm. Two different structured CsI:Tl phosphors with thickness 95 and 115 microm, respectively, have been optically coupled via a fiber optic plate to the array resulting in two different system configurations. The sensitivity of the two different system configurations was 43 and 47 electrons per x-ray incident on the sensor. The MTF at 10% of the two different system configurations was 9.5 and 9 cycles/mm with detective quantum efficiency of 0.45 and 0.48, respectively, close to zero frequency at approximately 0.44 microC/kg (1.72 mR) detector entrance exposure. The detector was quantum limited at low spatial frequencies and its performance was comparable with high resolution a: Si and charge coupled device based x-ray imagers. The detector also demonstrates almost an order of magnitude lower noise than active matrix flat panel imagers. The results suggest that CMOS active pixel sensors when coupled to structured CsI:Tl can be used for conventional and advanced digital mammography due to their low noise, high resolution performance.
50
XCOM: Photon Cross Section Database (version 1.2)
M. J. Berger, J.H. Hubbell, S. M. Seltzer et al. · 1999 · 857 citations
Digital tomosynthesis in breast imaging.
Loren T. Niklason, Bradley Christian, Laura E. Niklason et al. · Radiology · 1997 · 762 citations
Radiology · 2001 · 720 citations
Dedicated Breast CT: Radiation Dose and Image Quality Evaluation
John M. Boone, Thomas R. Nelson, Karen K. Lindfors et al. · Radiology · 2001 · 464 citations