Tracheal stenosis associated with a low pressure cuffed endotracheal tube

T. L. Bradbeer, Michael L. James, J. W. Sear, J.F. Searle, R. Stacey

Anaesthesia · 1976 · 10 citations · 11 references

DOIFull text

Open access

Concepts

Abstract

Tracheal stenosis as a complication of prolonged endotracheal intubation is well recognised, but to date there have been few if any reports of stenosis associated with the use of the new low pressure (or floppy) cuffed endotracheal tube. Case history HistoryThe patient, a 27-year-old married woman, was admitted to the Intensive Therapy Unit on 22 July, 1975 at 03.00 hours with a suspected overdose of diazepam and tricyclic antidepressants.Because of her level of consciousness, there was trouble maintaining an adequate airway; and she was therefore intubated with an 8 mm low pressure cuffed Portex tube.No relaxant was used, and there was no difficulty experienced in intubating her.The arterial blood-gas tensions were oxygen (Pao, 99 mmHg) and carbon dioxide (Paco, 38 mmHg).The patient had a blood pressure of 140/90 mmHg. Previous historyThere was a past history of a similar overdose of tricyclic antidepressants in 1973, but this had not necessitated intubation.However, intubation had been carried out on at least three previous occasions for obstetric procedures-the last being in July, 1971 for an emergency lower segment Caesarean section; on this last occasion, an 8 mm cuffed red rubber tube had been used, and the anaesthetist noted that it was a tight fit. Treatment and progressOver the following 48 hours, the patient breathed oxygen via an East Radcliffe blower