Physiological Measurement · 2010 · 62 citations · 32 references
EngineeringComputer ScienceElectrical EngineeringBiomedical Signal ProcessingMachine LearningTime Series AnalysisElectroencephalogram AnalysisElectroencephalogram Signal ProcessingElectroencephalographic MonitoringElectroencephalographyNeonatal NeurologySeizure ClassificationEeg-based Seizure DetectionElectroencephalogram ClassificationElectroencephalographic Pattern ClassificationElectroencephalography-based Seizure ClassificationEpileptic Seizure DetectionGaussian Mixture ModelsSeizure DetectionSeizures
A real-time neonatal seizure detection system is proposed based on a Gaussian mixture model classifier. The system includes feature transformation techniques and classifier output postprocessing. The detector was evaluated on a database of 20 patients with 330 h of recordings. A detailed analysis of the choice of parameters for the detector is provided. A mean good detection rate of 79% was obtained with only 0.5 false detections per hour. A thorough review of all misclassified events was performed, from which a number of patterns causing false detections were identified.
32