Physics in Medicine and Biology · 2003 · 64 citations · 32 references
MedicineNuclear MedicineRadiologyBiomedical ImagingDiagnostic ImagingDiagnostic RadiologyDetector TechnologyImagingPositron Emission TomographyPositron Emission Tomography PhysicsRadiation Imaging DetectorsRadiation Imaging SystemsDetector Response EstimationDetector Spatial ResolutionImaging ResolutionPet QuantificationPoint Spread FunctionPoint Spread Function AnalysisSpatial Resolution AnalysisSpatial Resolution Measurement
The optimization of spatial resolution is a critical consideration in the design of small-diameter positron emission tomography (PET) scanners for animal imaging, and is often addressed with Monte Carlo simulations. As a faster and simpler solution, we have developed a new analytical model of the PET detector response function, and implemented the model for a small single-slice, multilayer PET scanner. The accuracy of the model has been assessed by comparison with both Monte Carlo simulations and experimental measurements published in the literature. Results from the analytical model agreed well with the Monte Carlo method, being noise free and two to three orders of magnitude faster. The only major discrepancy was a slight underestimation of the width of the point spread function by the analytical method as inter-crystal scatter is neglected. We observed good agreement between the predictions of the model and experimental measurements. For two large-diameter scanners additional discrepancies were seen due to photon acollinearity, which is not considered in the model. We have shown that the simple and fast analytical detector response function model can provide accurate estimates of spatial resolution for small-diameter PET scanners, and could be a useful tool for several applications, complementing or cross-validating other simulation methods.
32
Correction for partial volume effects in PET: principle and validation.
Olivier Rousset, Yilong Ma, Alan C. Evans · PubMed · 1998 · 934 citations
Hans W. Müller‐Gärtner, Jonathan M. Links, Jerry L. Prince et al. · Journal of Cerebral Blood Flow & Metabolism · 1992 · 758 citations
Medicine, Neuroscience, Radiology +17
Comparative evaluation of MR-based partial-volume correction schemes for PET.
Carolyn C. Meltzer, Paul E. Kinahan, Phil J. Greer et al. · PubMed · 1999 · 252 citations
Development of a PET detector system compatible with MRI/NMR systems
Yiping Shao, Simon R. Cherry, Keyvan Farahani et al. · IEEE Transactions on Nuclear Science · 1997 · 190 citations