MedicineCardiologyRadiologyDiagnostic ImagingDiagnostic RadiologyRadiation DosimetryCardiac ImagingCardiothoracic ImagingComputed TomographyCoronary AngiographyCoronary Artery ImagingImage Quality AssessmentCardiac Computed TomographyCardiac Radiation DosimetryComputed Tomography Coronary AngiographyCoronary Ct AngiographyCoronary Lesion AssessmentCoronary Stenosis AssessmentHeart RateImage Acquisition Quality
OBJECTIVE: The purpose of this study was to compare prospective ECG-triggered and retrospective ECG-gated coronary 64-MDCT angiography as to radiation dose, image quality, accuracy of stenosis measurement, and CT densitometry. MATERIALS AND METHODS: Coronary artery models (n = 3) with different plaque densities (approximately 50, approximately 110, and approximately 1,000 H) on a cardiac phantom were scanned in variable heart rate sequences (n = 14) with both prospective ECG-triggered and retrospective ECG-gated scanning. Radiation dose, image quality graded by motion and stairstep artifacts (grade 1, excellent, to grade 4, poor, with grades 1 and 2 defined as satisfactory), accuracy of stenosis measurement (area; 18%, 50%, and 82%), and CT densitometry of plaques (soft, approximately 50; and intermediate, approximately 110 H) were compared between the two protocols using the Mann-Whitney U test and repeated measures. RESULTS: The radiation dose of prospective ECG-triggered CT angiography (CTA) (3.0 mSv) was lower than that of retrospective ECG-gated CTA (11.7-13.0 mSv) when the same tube current (mA) and voltage (kVp) were used in both methods. Prospective ECG-triggered CTA images were assigned a satisfactory quality rating in stable heart rate up to 75 beats per minute (bpm) when using the minimal X-ray exposure time. In this range, there were no significant differences in stenosis measurement (p = 0.17) and CT densitometry (p = 0.93) between the two protocols. CONCLUSION: Prospective ECG-triggered coronary 64-MDCT has the potential to reduce radiation exposure while maintaining the diagnostic performance of retrospective ECG-gated coronary 64-MDCT.
39
Accuracy of MSCT coronary angiography with 64-slice technology: first experience
Sebastian Leschka, Hatem Alkadhi, André Plass et al. · European Heart Journal · 2005 · 963 citations · Full text
Medicine, Cardiology, Radiology +17
Stephen Schroeder, Andreas F. Kopp, Andreas Baumbach et al. · Journal of the American College of Cardiology · 2001 · 733 citations
Medicine, Cardiology, Radiology +17