AIP conference proceedings · 2012 · 10 citations · 0 references
EngineeringMaterials ScienceNuclear EngineeringNuclear InstrumentationNuclear MaterialsUltrasoundTransducer TechnologyUltrasonicsUltrasound InstrumentationUltrasound PhysicsFast Spectrum ReactorsImmersion TransducersLinear Array TransducersPhased Array TransducersSingle-element TransducersTransducersUltrasonic Transducer ArraysUltrasonic Transducers
Liquid sodium is used as the coolant in some fast spectrum nuclear reactors. This material is optically opaque. To facilitate operations and maintenance activities, an ultrasonic under-sodium viewing system has been developed. In the USA, the technology was successfully demonstrated in the 1970s and, over the intervening 30+ years, the capability was lost. This paper reports materials challenges encountered in developing both single-element and linear phased-array 2-MHz transducers that must operate at temperatures up to 260°C. The critical issues are fundamentally material selection: the ability of a transducer to be immersed into liquid sodium and function at 260°C, to achieve wetting and transmission of ultrasound into the sodium, and to be able to be removed and re-used.