BMJ · 1971 · 132 citations · 4 references
MedicineOrthopaedic SurgeryOrthopedic SurgeryImplant SurgeryOrthopaedic BiomaterialsOrthopedic BiomaterialsBone CementsImplant MaterialsArterial Blood Pressure ControlArterial Blood Pressure MeasurementCement InfiltrationPilot Study DesignPostoperative Hypotension
A pilot study has shown that there is usually but not invariably a fall in systemic arterial blood pressure within 90 seconds of implanting acrylic cement into the femoral shaft during hip arthroplasty. There is usually no change in arterial blood pressure on implanting acrylic cement into the acetabulum. The observed hypotension may be due to absorption of monomer or additives into the circulation, but the role of other factors needs investigation.
4
Cardiac arrest associated with bone cement.
J. Powell, Patrick J. McGrath, Subhrajit Lahiri et al. · BMJ · 1970 · 105 citations · Full text