Circulation · 1986 · 117 citations · 11 references
MedicineCardiologyCardiothoracic SurgeryElectrophysiologyInterventional CardiologyCardiac PacingCardiogenic ShockCatheter Electrode TechnologyImplantable Cardioverter DefibrillatorsPulse Sequences
Wider applicability of an implantable automatic defibrillator depends on achieving internal cardiac defibrillation consistently with the lowest possible energy. In animal studies, we have found that the cardiac defibrillation threshold could be reduced when sequential shocks separated in time and spacially arranged were delivered to the heart. We compared internal cardiac defibrillation using a single pulse shock delivered through an intravascular catheter with this new method for internal cardiac defibrillation in patients undergoing cardiac surgery for the correction of arrhythmias. For the single pulse shock and the first pulse of the sequential pulse shock, current was passed through an intravascular catheter with the catheter cathode at the apex of the right ventricle and the anode at the superior vena cava-atrial junction region. The second pulse of the sequential pulse countershock was delivered between the catheter cathode in the right ventricular apex and an oval plaque electrode secured on the laterobasal left ventricular epicardium as anode. With the single pulse alone for shock delivery, 12 patients could be defibrillated with an average of 20.1 +/- 16.8 J, with a corresponding leading-edge peak voltage and current of 836 +/- 319 V and 9.4 +/- 4.5 A, respectively. However, two of the patients could not be defibrillated with energies below 50 J. With the sequential pulse shock delivery, a significant reduction in all values were recorded. Mean total energy for defibrillation averaged 7.7 +/- 6.0 J. Leading-edge peak voltage and current from the catheter averaged 430 +/- 148 V and 5.0 +/- 2.8 A, respectively.(ABSTRACT TRUNCATED AT 250 WORDS)
11
Feasibility and Effectiveness of Low-Energy Catheter Defibrillation in Man
M. Mirowski, Morton M. Mower, Vincent L. Gott et al. · Circulation · 1973 · 151 citations · Full text
Patterns of Ventricular Activity During Catheter Defibrillation
Morton M. Mower, M. Mirowski, Joseph F. Spear · Circulation · 1974 · 121 citations · Full text
Medicine, Cardiology, Physiology +17
Early Experience with an Implantable Cardioverter
Douglas P. Zipes, James J. Heger, William M. Miles et al. · New England Journal of Medicine · 1984 · 108 citations
Medicine, Anesthesiology, Cardiology +16