Investigative Radiology · 1974 · 15 citations · 0 references
MedicineCardiologyVeterinary PhysiologyCanine Internal MedicineCardiovascular PharmacotherapyHemodynamic ManagementCardiovascular MedicineCardiovascular PhysiologyCirculatory PhysiologyHemodynamic PharmacologyHemodynamicsVasopressor TherapyBlood FlowBlood PressureCardiac OutputCoronary Flow AssessmentElectromagnetic Flow SensorsHeart RateIschemic Vascular Changes
Changes in mean aortic blood pressure, cardiac output and coronary blood flow. were monitored in 6 dogs during infusion of vasopressin (Pitressin) into the superior mesenteric artery. Changes in flow were measured using electromagnetic flow probes placed on the ascending aorta and on the circumflex branch of the left coronary artery. Three dogs infused at 0.2 u/min showed a prompt 25% decrease in coronary artery flow and 47% decrease in cardiac output; at 0.4 u/min the decrements were 35% and 63% respectively. There was a 12- 19% decrease in heart rate, but in most animals no significant change occurred in mean aortic pressure. Premature ventricular contractions frequently were observed during the initial few minutes of the infusion, particularly with higher doses, but electrocardiograms showed no ischemic changes which could be attributed to vasopressin. With the increasing use of intra-arterial vasopressin infusions for control of gastrointestinal bleeding, careful monitoring of the cardiac response is recommended, especially in older patients and individuals with a history of cardiac disease.