The Axial Flow Molecular Pump : 3rd Report, Trial Manufacture and Performance Test

Tadashi Sawada, Osamu TANIGUCHI

Bulletin of JSME · 1973 · 12 citations · 0 references

DOIFull text

Open access

Concepts

Abstract

The operating mechanism of an axial flow molecular pump has already been reported in the first and second reports of this study. On the basis of the results of these reports, a method for determining the blade row arrangement is proposed. Then, an axial flow molecular pump is designed and manufactured for trial. Lastly, the performance of the manufactured pump is tested by experiments. The ultimate pressure of 5.2×10-9 mmHg and the pumping speed of 670 l/sec for room temperature nitrogen are obtained. These measured values agrees with the predicted values.