Journal of Occupational Health · 2005 · 17 citations · 6 references
Public HealthEnvironmental SciencesToxicologyEnvironmental ToxicologyOccupational HealthOccupational ToxicologyAir QualityExposure MonitoringHeavy Metal ContaminationLead ExposureLead ToxicologyParticulate MatterBattery ManufacturingBiological MonitoringBlood Lead Level TestingLead BiomarkersLead Exposure BiomonitoringLead Inhalation ExposureOccupational Lead ExposureRespirable Particulate Matter
Environmental and Biological Monitoring in a Lead Acid Battery Manufacturing Unit in India: B Ravichandran, et al. Regional Occupational Health Centre, Bangalore Medical College Campus, India — An environmental and biological monitoring of a lead acid battery manufacturing unit was carried out to measure the respirable particulate matter, lead content in working atmosphere and blood lead levels of workers employed in different sections. The results showed high mean air lead concentration in buffing (1444.45 µg/m 3 ), plate cutting (430.14 µg/m 3 ) and pasting (277.48 µg/m 3 ) sections. The mean blood lead levels of employees in these sections were also higher than the values prescribed by ACGIH.
6
Validity of lead exposure markers in diagnosis and surveillance
Joseph H. Graziano · Clinical Chemistry · 1994 · 46 citations · Full text
Pharmacy, Biochemistry, Toxicology +17
Possible oral lead intake via contaminated facial skin
Kanae Karita, Toshiaki Shinozaki, K Tomita et al. · The Science of The Total Environment · 1997 · 29 citations
Blood Lead Levels in Copper Smelter Workers in Japan.
Kanae Karita, Toshiaki Shinozaki, Eiji Yano et al. · Industrial Health · 2000 · 19 citations · Full text