Circulation · 1988 · 59 citations · 20 references
MedicineRadiologySurgeryCardiothoracic SurgeryDiagnostic ImagingDiagnostic RadiologyCongenital Heart Disease ImagingMagnetic Resonance ImagingThoracic SurgeryAzygos Venous SystemCardiac Cine ImagingCine Magnetic Resonance ImagingCongenital Valvular Heart DiseaseRight Ventricular ImagingRight Ventricular Outflow Tract ObstructionRight Ventricular Systolic Function
Cine magnetic resonance imaging (MRI) was used for postoperative evaluation of eight patients who underwent intra-atrial baffle procedure for surgical repair of D-transposition of the great arteries (D-TGA). Their ages ranged from 9 months to 8 years. Younger patients were sedated with chloral hydrate (80 to 100 mg/kg) orally. MRI was performed with use of a General Electric Signa system operating at a field strength of 1.5 tesla. A body or head coil was used depending on the size of the patient. Images were obtained by use of a technique of gradient-recalled acquisition in steady state (GRASS) that utilizes a low flip angle and shorter repetition and echo times. Five patients had widely patent venae cavae and three had superior vena caval obstruction at the junction of the right atrium with a dilated azygos vein. There was no evidence of pulmonary venous obstruction in any of the patients. Right ventricular function was assessed in four patients and their ejection fractions ranged from 58% to 81%. Tricuspid and mitral regurgitation were observed in three and two patients, respectively. Both right and left ventricular outflow tracts were well visualized and showed no evidence of obstruction. Cine MRI is an entirely noninvasive, nonionizing, and safe procedure in young patients and appears to be a valuable alternative method for evaluating patients after surgical repair of D-TGA. With advancing technologies and an accumulation of experience with cine MRI, it appears that this new technique will play an important role in patient care for children with congenital heart disease.
20
FLASH imaging. Rapid NMR imaging using low flip-angle pulses
Axel Haase, Jens Frahm, D. Matthaei et al. · Journal of Magnetic Resonance (1969) · 1986 · 832 citations
Measurement of right and left ventricular volumes in healthy individuals with cine MR imaging.
Udo Sechtem, P W Pflugfelder, Robert G. Gould et al. · Radiology · 1987 · 409 citations
Medicine, Cardiology, Radiology +17
Cine MR imaging: potential for the evaluation of cardiovascular function
Udo Sechtem, P W Pflugfelder, RG Gould et al. · American Journal of Roentgenology · 1987 · 251 citations
Medicine, Cardiology, Radiology +12
Congenital heart disease: gated MR imaging in 72 patients.
D Didier, C B Higgins, M R Fisher et al. · Radiology · 1986 · 163 citations
Medicine, Cardiology, Radiology +17